Specifications |
ECG |
Lead type | 3-lead or 5-lead selectable |
Lead selection, 3-lead | I, II, III |
Lead selection, 5-lead | I, II, III, aVR, aVL, aVF, V |
HR measurement | Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm |
HR accuracy | ±5 bpm or ±1 %, whichever is greater |
Arrhythmia | 21 calls |
ST measurement range | -2.5 mV – 2.5 mV |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s |
Gain selection | x 1/4, x 1/2, x 1, x 2, x 4, Auto |
Pacemaker detection | Yes |
Protection | Against electrosurgical interference and defibrillation |
Non-invasive blood pressure (NBP) |
Method | Automatic oscillometric |
Parameters | SYS/DIA/MAP/Pulse Rate |
Operating mode | Manual/Auto/STAT |
Auto measure intervals | 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes |
Units | mmHg/kPa |
Cuff pressure range, adult / pediatric | 0 – 300 mmHg ( 0 kPa – 40.0 kPa) |
Cuff pressure range, neonate | 0 – 150 mmHg ( 0 kPa – 20.0 kPa) |
Systolic measurement range, adult/ pediatric | 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa) |
Systolic measurement range, neonate | 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa) |
Diastolic measurement range, adult / pediatric | 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa) |
Diastolic measurement range, neonate | 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa) |
MAP measurement range, adult / pediatric | 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa) |
MAP measurement range, neonate | 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa) |
Accuracy, maximum standard deviation | 8 mmHg (1.1 kPa) |
Accuracy, mean error | ±5 mmHg (±0.7 kPa) |
Pulse rate range | 40 bpm – 240 bpm |
Pulse rate accuracy | ±5bpm or ±5%, whichever is greater |
SpO2 (Philips SpO2 technology) |
Measurement range | 0 – 100 % |
Accuracy | 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Pulse rate range | 30 bpm – 300 bpm |
Pulse rate accuracy | ±2 bpm or ±2%, whichever is greater |
Perfusion index | Yes |
Respiration (RESP) |
Measurement method | Thoracic impedance |
Measurement range | 0 rpm – 150 rpm |
Accuracy | 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined |
Gain selection | x 1/2, x 1, x 2 |
Apnea alarm | Yes, 10 – 60 s |
Work mode | Auto or manual (threshold) |
RESP lead | RA-LL |
Temperature (TEMP, 2-channel) |
Measurement range | 0 – 50? (32? – 122?) |
Resolution | 0.1? (0.2?) |
Accuracy | ±0.1? (±0.2?) (without sensor) |
Units | ? / ? |
Minimum measuring time | Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes |
Capnopgraphy (etCO2, optional) |
Method | Microstream, infrared absorption (Oridion) |
Parameters | awRR, etCO?, inCO? |
Measurement range | 0 – 99 mmHg (0 kPa – 13.2 kPa) |
Accuracy C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) | ±2 mmHg (±0.28 kPa) |
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) | ± (5% of reading 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa) |
awRR range | 0-150 rpm |
awRR accuracy, 3 rpm – 70 rpm | ±1 rpm |
awRR accuracy, 71 rpm – 120 rpm | ±2 rpm |
awRR accuracy, 121 rpm – 150 rpm | ±3 rpm |
Invasive Blood Pressure |
Accuracy | ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater |
Invasive blood pressure (IBP, 2-channel, optional) |
Parameters | SYS/DIA/MAP/Pulse Rate |
Measurement range | -50 – 400 mmHg (-6.6 kPa – 53.3 kPa) |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Resolution | 1 mmHg (0.13 kPa) |
Units | mmHg/kPa/cmH?O |
Transducer sensitivity | 5 uV/V/mmHg |
Pulse rate range | 30 bpm – 254 bpm |
Pulse rate accuracy | ±2bpm or ±2%, whichever is greater |
Sampling rate | 62.5 samples per second |
Recorder (optional) |
Type | Built-in thermal recorder, 3 channels |
Print mode | Real-time recording, timed recording, alarm-activated recording |
Print speed | Auto, 12.5 mm/s, 25 mm/s, 50 mm/s |
Display |
Type | Color TFT LCD, 4:3 |
Size | 10.4 611:631″ |
Resolution | 800 x 600 pixels |
Channels | Max 11 channels (auto waveform channel height adjustment) |
Power supply |
AC power input | 100 – 240 VAC, 50/60 Hz |
Battery | Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery) |
Weight and dimensions |
Net weight | Approx. 3.5 kg without battery |
Dimensions (w x d x h) | 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.) |
Safety approval and quality system |
Safety standard | IEC 60601-1-2:2014 |
Electromagnetic environment | IEC 60601-1-2:2000/A1:2014 |
Quality system | ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC |
Water proof | IPX1 |
Data review and storage |
Data review and storage | 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events |
External interface (standard) |
External interface | ECG analog output VGA output Nurse call LAN USB |
Cardiac Output (optional) |
Measurement method | Right heart thermodilution |
Measurement range | 0.1 l/min – 20.0 l/min |
Measurement accuracy | ±0.2 l/min or ±10 %, whichever is greater |
Blood temperature range | 27? – 43? (80.6? – 109.4?) |
Blood temperature accuracy | ± 0.1? |
Injection temperature | 0? – 27? (32? – 80.6?) |