Electrosurgical Diathermy EB-05 Healforce

Electrosurgical Diathermy EB-05 Healforce

Features:

EB-05 can be used in various operations such as general surgery, dermatology, plastic surgery, endoscopy, vascular surgery, heart / thoracic surgery, minimally invasive surgery, and ophthalmology.

Monopolar
Cutting mode : Pure: 400Watts 500 Load (OHMS) 2300V 1.5 Crest Factor.
Cutting mode : Blend1: 300 Watts 500 Load (OHMS) 2700V 2.1 Crest Factor.
Cutting mode : Blend2: 200Watts 500 Load (OHMS) 3.200V 2.5 Crest Factor.
Cutting mode : Blend3: 150Watts 500 Load (OHMS) 3.700V 3.1 Crest Factor.
Coagulation mode : Point: 120Watts 500 Load (OHMS) 5.600V 6.1 Crest Factor.
Coagulation mode : Soft: 120Watts 500 Load (OHMS) 3.400V 6.1 Crest Factor.
Coagulation mode : Spray: 120Watts 500 Load (OHMS) 8.500V 8.3 Crest Factor.
Bipolar
Cutting mode : Standard: 70Watts 200 Load (OHMS) 1.450V 1.5 Crest Factor.
Coagulation mode : Standard: 70Watts 500 Load (OHMS) 240V 1.5 Crest Factor.
Coagulation mode : Precise: 70Watts 200 Load (OHMS) 360V1.5 Crest Factor.
Accessory & Supply Connection
Finger-switch Pencil: 2
Foot-Switch Pencil: 1
Patient return electro code: 1
Footswitch: 1
AC power supply: 1
Equipotential bonding: 1
Power feature
Rate frequency: 512kHz (110240v Ac,6050Hz).
Isolated output: YES.
Quantitative display of contact area: YES, for ”Split” type of neutral electro code.
Contact area indicator lamp: 10 lamps (one for 10% contact), alarm beep and flicker if contact<20%.
SplitSolid neutral electrode definition: YES, ”Split” or ”Solid” indicator lamp lights up.
Adjustable alarm volume: YES
Operational duty cycle:  10 seconds ON, 30 seconds OFF.
Cooling method: Convection
Regulation
Type according to EN 60601-1: CF.
Protection class to EN 60601-1: Class 1.
Classification acc. to MDD 9342EEC: llb.
Physical
Dimension (WxDxH): 460*410*160mm.
Weight: 11.2 Kg.
SKU: HA - 1291 Category:

Description

Electrosurgical Diathermy EB-05 Healforce

Product Description:

EB-05 is flexible electrosurgery designed to deliver regular and enhanced argon. It has 10 separate power sitting, system memory of 9 streams, a floating output of max. 400 watts.

Features:

  • Max output controlled by a microprocessor.
  • Four hundred watts (all floating).
  • Monopolar modes and 3 Bipolar modes of control.
  • Automatic power adjustment and tissue variation compensation.
  • Return control of electrodes and tissue variance compensation.
  • The memory of the program’s 9 streams.
  • TURP, TUVP capability.
  • It is possible to configure different instruments simultaneously.

Brand

Heal Force

There are no reviews yet.