Specifications:
Display:
15.6″ color TFT screen
Resolution: 1366*768 dpi
Number of traces: 12 waveforms
Battery:
Rechargeable lithium battery
Networking Wired Or Wireless:
LAN: 1 standard RJ45 Port
WLAN: IEEE802.11 b/g/n
USB: 2 USB connectors
SO: 1 SD card Socket
VGA: 1 standard color VGA monitor connector
Output: 1 standard connector for Nurse Call, Defib Sync Analog Output
Recorder (Optional)
Built-in, thermal dot array
Waveform: 3 channels
Paper width: 50mm
Print speed: 12.5 mm/s, 25mm/s, 50mm/s
ECG:
Lead Type: 3-lead, 5-lead, 12-lead
ECG waveform: 2 channels, 7 channels, 12 channels
Gain selection: x0.25, x0.5; x1; x2
Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
Filter: Diagnostic mode: 0.05-150Hz
Monitoring mode: 0.5-40 Hz
Surgery mode: 1-20Hz
Notch: 50Hz, 60Hz
Heart Rate range: Adult: 15-300bpm;
Pediatric! Neonate: 15-350bpm;
Accuracy: ±1 bpm or ±1 %, whichever is greater
Resolution: ±1bpm
Respiration:
Method: Trans-thoracic impedance
Operation modes: Auto/ Manual
Measurement range: Adult: 0-120 bpm;
Neonate/Pediatric: 0-150 bpm
Apnea alarm delay: 1Os, 15s, 20s, 25s, 30s, 35s, 40s
Apnea Alarm: Selectable
Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s
Sp02:
Measurement range: 0-100%
Resolution: 1%
Accuracy: ±2% (70-100% Adult/Pediatric);
±3% (70-100% Neonate);
0-69% unspecified
Refreshing rate: 1s
Masimo SET®
SP02(0ptional)
Accuracy: ±2% (70-100% Adult/Pediatric, non-motion,low perfusion);
±3% (70-100% Neonate, non-motion);
±3% (70-100% motion);
0-69% unspecified
Pulse Rate:
Range: 0-254 bpm
Resolution: 1 bpm
Accuracy: ±3bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1s
NIBP:
Method: Automatic oscillometric
Operation modes: Manual/Auto I STAT
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range:
Range of systolic pressure: Adult Mode 40 -270 mmHg
Pediatric Mode 40 – 200 mmHg
Neonatal Mode 40 – 135 mmHg
Range of diastolic pressure: Adult Mode 10 – 210 mmHg
Pediatric Mode 10 – 150 mmHg
Neonatal Mode 10 – 100 mmHg
Range of mean pressure: Adult Mode 20- 230mmHg
Pediatric Mode 20 – 165mmHg
Neonatal Mode 20 – 110mmHg
Accuracy: Max mean error: ±5 mmHg
Measurement Interval: 1 ,2,3,4,5, 10, 15,30,60,90, 120,180,240,
480minutes
Over-pressure protection: Double safety protection
Cuff pressure range: 0-280 mmHg
Resolution: 1 mmHg
Temperature:
Accuracy: ±0.1 “C or ±0.2 “F (without probe)
Measurement range: 0-50″C (32 to 122 “F)
Channel: Two-channels
Resolution: 0.1 “C
Parameters: T1 , T2 and TD
IBP (Optional):
Channel: 2-channel
Measurement types: Systolic, Diastolic, Mean
Range:OmmHg-300mmHg
Resolution: 1 mmHg
Accuracy: ±2% or ±1 mmHg, whichever is greater (without sensor)
Sensitivity: 5uV/mmHgN
Impedance range: 300 to 3000
C.O. (Optional):
Method: Thermodilution
Range: C.O.: 0.1 to 20Umin
TB: 23 to 43’C
T1: 0 to 27’C
Accuracy : C.0.:±5% or ±0.1Umin, whichever is greater
TB, T1: ±0.1 ‘C (without sensor)
Phasein ISA:
SidestreamC02 (Optional)
Warm-up time: Full accuracy within 10 seconds
Sampling flow rate: 50ml/min ( /-10ml/min)
Accuracy: ± (0.2 % 2 % of the reading)
Measurement Range: 0 -15%
Rise time: 200ms, typical at 50ml/min flow rate
Respiration:
Method: Trans-thoracic impedance
Operation modes: Auto/ Manual
Measurement range: Adult: 0-120 bpm;
Neonate/Pediatric: 0-150 bpm
Apnea alarm delay: 1Os, 15s, 20s, 25s, 30s, 35s, 40s
Apnea Alarm: Selectable
Sweep Speed: 6.25mm/s, 12.5mm/s, 25mm/s
Pulse Rate:
Range: 0-254 bpm
Resolution: 1 bpm
Accuracy: ±3bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1s
Temperature:
Accuracy: ±0.1 “C or ±0.2 “F (without probe)
Measurement range: 0-50″C (32 to 122 “F)
Channel: Two-channels
Resolution: 0.1 “C
Parameters: T1 , T2 and TD